TC failure classifications

High / Low / Negligible per NR/L3/SIG/10047 Mod 03 โ€” determines FMS risk level, response and sign-back requirements.

High

  • SCWO โ€” automatic signal
  • SCWO โ€” signal working in auto / ARS
  • SCWO โ€” controlled signal
  • SCWO โ€” level crossing (except ABCL/AOCL/TMO with driver's indicator)
  • Showing clear with TC interrupter broken
  • TCOD โ€” occupied circuit clearing after correct TCOD
  • USR not timed out (poster only โ€” Appendix I rates this Low; see footnote)

Low

  • Indication-only circuits
  • ABCL/AOCL/TMO crossings only
  • Drop shunt >0.2ฮฉ below minimum

Negligible

  • Under 300ms
  • <1s striking in/out with abutting circuit occupied
  • After protection (special block) in place
  • Rusty rails โ€” TS11
  • Sequencing controls effective

Hazard index

Failure modeRIDDORHazardRatingClass
SCWO โ€” automatic signalYesPotential unsafe wrong-side condition (false clear)H9High
SCWO โ€” signal working in auto / ARSYesPotential unsafe wrong-side condition (false clear)H7High
SCWO โ€” controlled signal not in autoYesPotential unsafe wrong-side condition (false clear)H6High
Showing clear with TC interrupter brokenYesPotential unsafe wrong-side condition (false clear)H4High
TCOD โ€” occupied circuit clearing after a correct TCODYesPotential unsafe wrong-side condition (false clear)H4High
SCWO โ€” controlling a level crossing (except ABCL/AOCL/TMO)YesPotential unsafe wrong-side condition (false clear)H4High
SCWO โ€” route locking maintained, USR not timed outNoLimited / protected wrong-side conditionL2Low
SCWO โ€” ABCL/AOCL/TMO crossing onlyNoLimited / protected wrong-side conditionL2Low
Drop shunt โ‰ฅ0.2ฮฉ below minimumNoLimited / protected wrong-side conditionL2Low
SCWO โ€” indication-only circuitNoLimited / protected wrong-side conditionL1Low
SCWO โ€” under 300msNoNo credible hazardN0Negligible
SCWO โ€” sequencing controls effective (SSI8003-82)NoNo credible hazardN0Negligible
SCWO โ€” <1s striking out/in at TC boundary with abutting circuit occupiedNoNo credible hazardN0Negligible
SCWO โ€” after TS11 special block imposedNoNo credible hazardN0Negligible
Rusty rails โ€” TS11 arrangementsNoNo credible hazardN0Negligible

Classification per NR/L3/SIG/10047 Mod 03 ยง10.1. High classifications are RIDDOR-reportable; RIDDOR and S&TINCS referencing follows the same module.

Discrepancy: the 'Classifications of TC failures' poster shows 'SCWO โ€” route locking maintained, USR not timed out' as HIGH, whereas Appendix I rates it LOW (L2). Resolve with route S&T before relying on either โ€” treat as the higher classification until confirmed.